Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V
MRP-2002|FL-MRP2002
Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V
MRP-2002|FL-MRP2002
Fire-Lite Alarms by Honeywell
Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V
MRP-2002 | FL-MRP2002
Please sign in to view pricing and availability and to add to cart.
Overview
Specifications
Documents
Product Overview
The MRP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The MRP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The MRP-2002 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the FireLite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2002 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MRP-2002E offers the same features as the MRP-2002 but allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/ 120 VAC and 220/240 VAC versions of the panels.
Main Features
- Meets International Building Code IBC seismic requirements
- Adjustable pre-discharge, discharge and waterflow delay timers.
- Dual hazard operation
- Meets International Building Code (IBC) seismic requirements.
- Disable/Enable control per input zone and output zone.
- Extensive transient protection.
- Dual hazard operation.
- Adjustable pre-discharge, discharge and waterflow delay timers.
- Cross-zone (double-interlock) capability.
- Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
General Information
Name: Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V
Category: Fire-Lite Alarms by Honeywell, Fire, Fire Control Panels, Fire Alarm Control Panels
UPC Code: 783008109103
Country of Origin: United States. Country of origin is subject to change.
Specifications
-
ADI Part Number FL-MRP2002 Brand Name Fire-Lite Alarms by Honeywell Manufacturer Honeywell International, Inc Manufacturer Part Number MRP2002 Product Line MRP Product Model MRP-2002 Product Name MRP-2002 Fire Alarm Control Panel Product Series MRP Product Type Fire Alarm Control Panel
-
Maximum Number of Zones Supported 6 Number of Events Log 256 Number of Standard Zones 6 Panel Control Type Conventional
-
Battery Built-in Yes
-
Display Type LCD
-
Application/Usage Commercial
-
Input Voltage 120V AC
-
Limited Warranty 3 Year
-
Compatibility System Sensor i3 Series DetectorsFire-Lite:Smoke DetectorsPull StationsWaterflow DevicesTamper Switches Features 24 volt operation, 7.0 amps total 24 VDC output current, ANN-BUS connector for communication with optional devices 80-character LCD display (backlit) Real-time clock/calendar with daylight savings time control, Automatic battery charger with charger supervision, Built-in Programmer, Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001, Extensive transient protection Dual hazard operation Adjustable pre-discharge, discharge and waterflow delay timers Cross-zone (double-interlock) capability, FM Approved, Four programmable Style Y (Class B) output circuits - (special application power), History log with 256 event storage, Listed to UL Standard 864, 9th edition, Low AC voltage sense, Meets International Building Code (IBC) seismic requirements Disable/Enable control per input zone and output zone, Piezo sounder for alarm, trouble and supervisory, Resettable and non-resettable output power, Six programmable Style B (Class B) IDCs (Initiating Device Circuit) System Sensor i3 series detector compatible, Strobe synchronization, Three programmable Form-C relays Package Contents - MRP-2002 Fire Alarm Control Panel
- Backbox
- Power Supply
- Technical Manual
- Instruction Sheet