Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V

MRP-2002|FL-MRP2002

Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V

MRP-2002|FL-MRP2002

Sign In for Dealer Pricing

Become an ADI Customer
Image of FL-MRP2002
Fire-Lite Alarms by Honeywell

Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V

MRP-2002 | FL-MRP2002

Please sign in to view pricing and availability and to add to cart.

Overview
Specifications
Documents

Product Overview

The MRP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The MRP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The MRP-2002 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the FireLite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2002 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MRP-2002E offers the same features as the MRP-2002 but allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/ 120 VAC and 220/240 VAC versions of the panels.

Main Features

  • Meets International Building Code IBC seismic requirements
  • Adjustable pre-discharge, discharge and waterflow delay timers.
  • Dual hazard operation
  • Meets International Building Code (IBC) seismic requirements.
  • Disable/Enable control per input zone and output zone.
  • Extensive transient protection.
  • Dual hazard operation.
  • Adjustable pre-discharge, discharge and waterflow delay timers.
  • Cross-zone (double-interlock) capability.
  • Six programmable Style B (Class B) IDCs (Initiating Device Circuit).

General Information

Name: Fire-Lite MRP-2002 Single and Dual Hazard Agent Release Control Panel, 6-Zone and 24V
Category: Fire-Lite Alarms by Honeywell, Fire, Fire Control Panels, Fire Alarm Control Panels
UPC Code: 783008109103
Country of Origin: United States. Country of origin is subject to change.