adi-insite-us
ADI US App
ADI Global Distribution
ADI a Resideo company
menu
content loaded
Image of AX-MAXIAL77

Altronix MAXIMAL77FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 24VDC P/S at 9.7A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL77FV|AX-MAXIAL77

Altronix MAXIMAL77FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 24VDC P/S at 9.7A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL77FV|AX-MAXIAL77

Sign In for Dealer Pricing

Become an ADI Customer
Image of AX-MAXIAL77
Altronix

Altronix MAXIMAL77FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 24VDC P/S at 9.7A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL77FV | AX-MAXIAL77

Please sign in to view pricing and availability and to add to cart.

Overview
Specifications
Documents

Product Overview

Maximal77FV Access Power Controller distributes and switches power to access control systems and accessories. It converts a 220V AC (working range 198V AC - 256V AC), 50/60Hz input into sixteen (16) independently controlled 24V DC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.

Main Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
  • Normally open (NO) or normally closed (NC) dry contact input.
  • Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated at 1A 28V DC).
  • AC fail supervision (form "C" contacts)
  • Notification trigger is selectable for 30 seconds (factory set) or 2 hours
  • Low battery and battery presence supervision (form "C" contact)
  • Capacity: 12AH/12V DC (4 within enclosure); 40AH/65AH (requires separate enclosure)
  • Type Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous

General Information

Name: Altronix MAXIMAL77FV Access Power Controller with Power Supply / Chargers, 16 Fused Relay Outputs, Dual 24VDC P/S at 9.7A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
Category: Altronix, Access Control, Power Products, Access Power Controllers
UPC Code:
Country of Origin: . Country of origin is subject to change.

Specifications

Product Documents and Resources