Product Overview
The Initiating Device Circuit Expander (IDC-6) provides an additional 6 inputs per module. The panel supports up to thirty-one (31) IDC-6 modules. The circuits are power-limited and supervised. All inputs are suitable to monitor 2-wire smoke detectors. Smoke detectors shall be installed in compliance with NFPA 72. Inputs can also be used for automatic, manual, waterflow or supervisory service. The IDC-6 communicates via the PLink communication bus. The IDC-6 can be mounted in either the control panel cabinet, the intelligent power supply, AE-2, AE-8 or the AE-14 expander cabinet. Each card is mounted to the exclusive Stacker Bracket for secure and accessible mounting.
Installation
The IDC-6 is connected to the fire control panels using a 4-wire RS- 485 connection. The connection is power limited and supervised. The IDC-6 must be mounted in either a compatible fire alarm panel, the pSN-1000, or within 20 feet of the panel or power supply using the ae-2, ae-8, or the ae-14 expander cabinet. each card is mounted to the exclusive Stacker Bracket for secure and accessible mounting.
Main Features
- Mounts with included stacker bracket
- May mount in panel, accessory cabinet, ae-2, ae-8 or ae-14 accessory Cabinets or the pSN-1000/e power Supply
- provides 6 IDC Input Circuits
- Maximum 31 IDC-6 per panel
- Maximum p-Link wire length of 20 feet.
General Information
Specifications
-
ADI Part Number PL-IDC6 Brand Name Potter Electric Signal, LLC Manufacturer Potter Electric Signal, LLC Manufacturer Part Number IDC-6 Product Name IDC-6 Initiating Device Circuit Expander Product Type Expander Â
-
Maximum Operating Temperature 120°F (48.9°C) Minimum Operating Temperature 32°F (0°C) Â
-
Depth 1.1" Height 6" Width 4" Â
-
Compatibility IPA Series AFC/ARC Series PFC-4064 Â