Altronix AL1024ULACM Access Power Controller with Power Supply/Charger, 8 Fused Relay Outputs, 24VDC at 10A, BC400 Enclosure

Altronix AL1024ULACM Access Power Controller with Power Supply Charger, Fused Relay Outputs, 24VDC at 10A, BC400 Enclosure

AL1024ULACM|AX-1024ULACM

Altronix AL1024ULACM Access Power Controller with Power Supply Charger, Fused Relay Outputs, 24VDC at 10A, BC400 Enclosure

AL1024ULACM|AX-1024ULACM

Sign In for Dealer Pricing

Become an ADI Customer
Altronix AL1024ULACM Access Power Controller with Power Supply/Charger, 8 Fused Relay Outputs, 24VDC at 10A, BC400 Enclosure
Altronix

Altronix AL1024ULACM Access Power Controller with Power Supply Charger, Fused Relay Outputs, 24VDC at 10A, BC400 Enclosure

AL1024ULACM | AX-1024ULACM

Please sign in to view pricing and availability and to add to cart.

Overview
Specifications
Documents

Product Overview

Altronix ACM series distribute and switch power to access control systems and accessories. They convert a 115VAC, 60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Main Features

  • Eight (8) independently controlled outputs
  • Output options: Eight (8) Fail-Safe and/or Fail-Secure power outputs; Eight (8) form “C” 5A rated relay outputs; Any combination of the above
  • Eight (8) auxiliary power outputs (unswitched)
  • Output fuses are rated @ 3.5A
  • Filtered and electronically regulated outputs
  • Supervision: AC Fail/ Battery Fail and Battery Presence
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input b) Polarity reversal input from FACP signaling circuit
  • Built-in charger for sealed lead acid or gel type batteries

General Information

Name: Altronix AL1024ULACM Access Power Controller with Power Supply Charger, Fused Relay Outputs, 24VDC at 10A, BC400 Enclosure
Category: Altronix, Access Control, Batteries & Power Supplies, Power Products, Power Supplies & Boards, Access Power Controllers, Access Power Controllers
UPC Code: 782239935765
Country of Origin: United States. Country of origin is subject to change.

Specifications