Altronix EFLOW6NA8 Access Power Controller with Power Supply Charger, 8-Fused Relay Outputs, 12/24V DC, 6A, Auxiliary Output, FAI, 115V AC, BC400 Enclosure
Altronix EFLOW6NA8 Access Power Controller with Power Supply Charger, 8-Fused Relay Outputs, 12/24V DC, 6A, Auxiliary Output, FAI, 115V AC, BC400 Enclosure
Altronix EFLOW6NA8 Access Power Controller with Power Supply Charger, 8-Fused Relay Outputs, 12/24V DC, 6A, Auxiliary Output, FAI, 115V AC, BC400 Enclosure
EFLOW6NA8 | AX-EFL6NA8
Please sign in to view pricing and availability and to add to cart.
Product Overview
eFlow6NA8 distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs with a total of 6A continuous supply current. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Altronix eFlowNA series distribute and switch power to access control systems and accessories. They convert a 120VAC, 60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnec feature is individually selectable for any or all of the eight (8) outputs.Main Features
- Eight (8) independently controlled outputs.
- Output options: a) Eight (8) Fail-Safe and/or Fail Secure power outputs. b) Eight (8) form “C” 5A rated relay outputs. c) Any combination of the above.
- Eight (8) auxiliary power outputs (unswitched).
- Output fuses are rated @ 3.5A.
- Filtered and electronically regulated outputs.
- Supervision: - AC Fail - Battery Fail and Battery Presence - Low power shutdown
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Alarm output relay indicates that FACP input is triggered.
- Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input b) Polarity reversal input from FACP signaling circuit
- Built-in charger for sealed lead acid or gel type batteries.
General Information
Specifications
-
ADI Part Number AX-EFL6NA8 Brand Name Altronix Manufacturer Altronix Corporation Manufacturer Part Number EFLOW6NA8 Product Line eFlow Product Name Proprietary Power Supply Product Type Proprietary Power Supply Sector Access Control
-
Output Voltage 24V DC
-
NDAA Compliant Yes
-
Depth 5" Form Factor Wall Mount Width 12"
-
Input Voltage 120 V AC
-
Limited Warranty Lifetime
-
Compatibility Mag Locks Electric Strikes Magnetic Door Holders Emergency Egress Environmental Certification RoHS Environmentally Friendly Yes Package Contents - Proprietary Power Supply
- Multi-Output Access Power Controllers