APC APDU10450SM NetShelter Rack Power Distribution Unit, Advanced

APDU10450SM|2G-DU10450SM

APC APDU10450SM NetShelter Rack Power Distribution Unit, Advanced

APDU10450SM|2G-DU10450SM

Sign In for Dealer Pricing

Become an ADI Customer
Image of 2G-DU10450SM
APC by Schneider Electric

APC APDU10450SM NetShelter Rack Power Distribution Unit, Advanced

APDU10450SM | 2G-DU10450SM

Please sign in to view pricing and availability and to add to cart.

Overview
Specifications
Documents

Product Overview

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Main Features

  • Easily control your equipment remotely without any hassle with Switched with Metered-by-Outlet
  • IEC 60320 C13/C15/C19/C21 receptacle type to ensure maximum usability and reliable power output
  • Single Phase phase PDU provides dependable power output with maximum efficiency
  • IEC 60309 60A 3P+N+PE plug/connector type for reliable, productive connectivity and optimal power output
  • 415 V input voltage for optimal performance with maximum usability
  • 240 V AC output voltage for better reliance and maximum usability
  • 240 V AC output voltage for maximum dependability and added productivity

General Information

Name: APC APDU10450SM NetShelter Rack Power Distribution Unit, Advanced
Category: APC by Schneider Electric, Batteries & Power Supplies, Power Management, Power Distribution Units
UPC Code:
Country of Origin: . Country of origin is subject to change.

Specifications